Mux Demux 18CH CWDM

Mux Demux 18CH CWDM

Tsawg Insertion Poob
Low PDL
Epoxy dawb hauv kev kho qhov muag
High Isolation: Independent wavelengths uas tsis muaj crosstalk
Ib qho - fiber ntau muaj peev xwm nthuav dav: Ib txhij xa tawm ntawm 18 qhov kev pabcuam ywj pheej wavelengths ntawm ib qho fiber ntau
Kev khiav hauj lwm dav wavelength: Tag nrho cov kev pab cuam ntawm 1270nm-1610nm band
Txoj kev daws teeb meem tuaj yeem kho raws li cov neeg siv khoom thov
Xa kev nug

Shenzhen Optico Kev Sib Txuas Lus Co., Ltd. Thov koj xav tias dawb rau cov lag luam wholesale siab zoo customized khoom ntawm tus nqi sib tw peb lub Hoobkas. Yog tias koj muaj lus nug txog cov qauv dawb, thov koj xav email rau peb.

 

 

Khoom Profile

 

  • Qhov no Mux Demux 18CH CWDM yog tus qauv 1U khib-mount passive ntaus nrog pigtails. Nws ua haujlwm raws li ob qho tib si multiplexer thiab demultiplexer, txhawb nqa ob qho tib si wavelength multiplexing thiab demultiplexing. Siv ib qho fiber ntau, nws ua rau tib lub sijhawm sib kis ntawm 18 qhov sib txawv wavelength signals, txhim kho kev siv fiber ntau thiab txo cov nqi cabling. CWDM siv ib nrab ntawm -kab nplaum-dawb optical txoj kev thev naus laus zis, nthuav tawm cov yam ntxwv ua tau zoo xws li polarization insensitivity, kev sib cais siab, tsis tshua muaj crosstalk, tsis muaj qhov ntxig, thiab qhov kub tsis tshua muaj drift, ua kom ruaj khov thiab ruaj khov.

 

  • Qhov no Mux Demux 18CH CWDM los tus qauv nrog LC / UPC interfaces thiab tseem txhawb kev hloov kho ntawm lwm yam kev sib txuas lus, muab cov kev daws teeb meem raws li cov neeg siv khoom xav tau daim ntawv thov. Nws suav nrog tag nrho cov txheej txheem CWDM band los ntawm 1260nm txog 1620nm, muab kev sib raug zoo zoo thiab nthuav dav rau ntau yam kev pabcuam kis tau zoo xws li 1G/10G/25G Ethernet, SDH/SONET, 1/2/4/8/16G Fiber Channel, FTTx, thiab CATV.

 

Khoom Specifications

Parameter 4 CH UA 8 CH UA 16 CH UA 18 CH UA
Ua haujlwm wavelength (nm) 1260-1620
Channel Wavelength (nm) 1270,1290,...,1590,1610, lossis 1271,1291,...,1591,1611
Channel Spacing (nm) 20
Channel Passband (nm) CWL+/-6.5nm
Insertion poob (dB) Tsawg dua los yog sib npaug rau 1.2 Tsawg dua lossis sib npaug li 2.7 Tsawg dua lossis sib npaug 3.2 Tsawg dua lossis sib npaug li 3.7
Channel Pipple (dB) Tsawg dua los yog sib npaug li 0.5
Kev sib cais nyob ib sab (dB) >30
Tsis yog-Ib puag ncig (dB) >40
Polarization Hom Dispersion (ps) Tsawg dua los yog sib npaug li 0.2
Polarization Dependent Loss (dB) Tsawg dua los yog sib npaug li 0.2
Kev taw qhia (dB) >45
Rov qab poob (dB) >45
Kev tswj fais fab siab tshaj plaws (mW) 500
Ua haujlwm kub (degree) -5-70
Cia kub (degree) -40-85
Hom Fiber G657A1 lossis Customized
Txuas Customized
Pob Dimension (mm) 100×80×10 120×80×18
Lus ceeb toom:
* 1.Txhua qhov tsis muaj qhov sib txuas
* 2.Connector Poob: 0.2dB / txhua ntxiv

 

Khoom zoo

 

3CWDM

 

Tsawg l

6CWDM

 

High channel cais

Can reach Industry grade

 

Qib Industrial

 

Bidirectional Compatibility

 

WDM

 

WDM ib leeg fiber ntau bidirectional kis tau tus mob

WDM

 

WDM dual fiber ntau bidirectional kis tau tus mob

 

 

CWDM + DWDM networking

 

CWDM-DWDM

 

 Qhov CWDM no txhawb kev sib koom ua ke nrog DWDM ntom ntom wavelength faib cov cuab yeej kom ua tiav dual- txheej hybrid wavelength division multiplexing networking, zoo kawg nkaus daws qhov mob taw tes ntawm kev sib txuas lus bidirectional nrog cov bandwidth loj thiab ob peb optical fibers thoob plaws qhov chaw.

 

  • Kev Pab Cuam: Ob Qhov Chaw A thiab Qhov Chaw B tuaj yeem nkag mus rau ntau yam kev pabcuam, suav nrog kev cia, IP, video, keyboards, thiab cov ntaub ntawv tseem ceeb. Ntau pawg ntawm qhov ntom ntom ntom (C29-C36, C53-C60, thiab lwm yam) yog thawj zaug ua ke thiab sib cais siv DWDM cov khoom siv.

 

  • Core Multiplexing: Ib qho 18CH CWDM Mux Demux nqa lub teeb liab ua ke los ntawm ob lub DWDM teeb tsa ntawm ob lub wavelengths ywj siab, 1530nm thiab 1550nm, ua tiav qhov kev sib tw thib ob.

 

  • Txuas Txuas Txuas: Dual -wavelength bidirectional point- mus rau - taw tes ntev - kis tau tus mob tuaj yeem ua tiav siv ib khub ntawm qhov tsis pom kev liab qab optical fibers (Tsub Fiber), tsis tas yuav tsum muaj fiber ntau optic cable ntxiv.

 

  • Tej thaj chaw deb Demultiplexing: Qhov chaw nyob deb siv CWDM + DWDM mus ua ntu zus faib cov wavelengths, rov kho tag nrho cov kev pabcuam qub yam tsis muaj ntaub ntawv poob lossis kev pabcuam cuam tshuam thoob plaws tag nrho cov txheej txheem.

 

Nyob rau hauv passive WDM optical kis systems, CWDM (Coarse Wavelength Division Multiplexing) thiab DWDM (Dense Wavelength Division Multiplexing) tuaj yeem sib xyaw thiab sib xyaw kom yooj yim tsim kom ruaj khov thiab txhim khu kev ntseeg ntev ntev - kis tau tus mob network daws teeb meem raws li xav tau. Cov qauv no tsis tsuas yog txo qis qhov kev nkag mus ntawm tag nrho qhov txuas tab sis kuj txo qis cov khoom siv kho qhov muag fiber ntau, txuag tau txiaj ntsig zoo ntawm fiber ntau txuas.

 

FAQ

FAQ

Q: WDM yog dab tsi?

A: WDM yog ib qho tseem ceeb ntawm kev sib txuas lus kho qhov muag thev naus laus zis rau siab - muaj peev xwm sib cuam tshuam - qhov chaw xa tawm. Nws tuaj yeem xa tawm ntau lub teeb liab ntawm qhov sib txawv wavelengths nyob rau hauv ib qho kev kho qhov muag fiber ntau, txhim kho lub network bandwidth. Kev siv WDM thev naus laus zis tsis yog tsuas yog siv cov khoom siv kho qhov muag fiber ntau zoo xwb tab sis kuj txo cov nqi nthuav dav thiab ua kom zoo dua kev siv network thiab kev siv nyiaj tu.

Q: CWDM thiab DWDM yog dab tsi?

A: Ob qho tib si CWDM thiab DWDM yog los ntawm WDM thev naus laus zis, tab sis lawv sib txawv hauv cov ntsiab lus wavelength thiab cov xwm txheej siv tau.CWDM muaj cov qauv yooj yim thiab hloov tau yooj yim, hloov mus rau ntau yam fiber ntau optic tes hauj lwm, thiab feem ntau yog siv rau hauv point -rau- taw tes architectures rau kev lag luam thiab kev sib txuas lus sib txuas rau ntau lub network.Dmploytan feem ntau yog qhov chaw sib txuas lus. nplhaib topology, thiab yog dav siv nyob rau hauv cov ntaub ntawv chaw interconnects, nyiaj txiag ntiag tug network, thiab lwm yam scenarios.

Q: Qhov txawv ntawm CWDM thiab DWDM yog dab tsi?

A: Qhov sib txawv tseem ceeb ntawm DWDM thiab CWDM nyob rau hauv qhov sib nrug ntawm cov channel, nrog CWDM muaj qhov sib txawv ntawm cov channel loj dua li DWDM. Hais txog kev sib kis deb, CWDM qhov siab tshaj plaws yog kwv yees li 160km, uas yog txwv tsis pub; DWDM, ntawm qhov tod tes, txhawb kev sib kis ntev dua. Hais txog tus nqi, DWDM yuav tsum tau txias laser tshuab, ua rau nws kim dua; tag nrho cov kab ke feem ntau raug nqi 4 mus rau 5 npaug ntau dua CWDM.

 

 

Cim npe nrov: mux demux 18ch cwdm, Suav teb, manufacturers, lwm tus neeg, Hoobkas, lag luam wholesale, customized

Parameter

Chav tsev

Tus nqi

Xov tooj

-

2

4

8

16

Channel Chaw

nm

20

Central Wavelength

nm

1271~1611

Ua haujlwm wavelength

nm

1260-1460 lossis 1460-1620 lossis 1260-1620

Passband

nm

LUAS ± 6.5

Hla band Flatness

dB

Tsawg dua los yog sib npaug li 0.5

Insertion Poob (Hom.)

dB

0.8

1.3

2.4

4.6

Insertion poob (Max.)

dB

0.9

1.5

2.8

5.0

Kev sib cais Channel

dB

Ntau tshaj los yog sib npaug rau 30

Tsis yog-Channel Isolation nyob ib sab

dB

Ntau dua lossis sib npaug li 40

Polarization Hom Dispersion

ps

Tsawg dua los yog sib npaug li 0.1

Tsawg dua los yog sib npaug li 0.1

Tsawg dua los yog sib npaug li 0.15

Tsawg dua los yog sib npaug li 0.15

Polarization Dependent Poob

dB

Tsawg dua los yog sib npaug li 0.1

Tsawg dua los yog sib npaug li 0.15

Tsawg dua los yog sib npaug li 0.2

Tsawg dua los yog sib npaug li 0.25

Rov Los Los

dB

Ntau tshaj los yog sib npaug rau 50

Kev taw qhia

dB

Ntau tshaj los yog sib npaug rau 50

Insertion Loss Temperature Sensitivity

dB / degree

0.005

0.005

0.007

0.007

Wavelength Temperature Shifting

nm / degree

0.002

Kev ua haujlwm kub

degree

-10~+70

Cia Kub

degree

-40~+85

Pob Dimension

mm

ABS lub thawv: 100X80X10mm lossis customized